Sensors

Dell™ Remote Access Controller 5 Firmware Version 1.40 User's Guide

  Battery Probes

  Fan Probes

  Chassis Intrusion Probes

  Power Supplies Probes

  Hardware Performance Probes

  Power Monitoring Probes

  Temperature Probes

  Voltage Probes


Hardware sensors or probes help you to monitor the systems on your network in a more efficient way by enabling you to take appropriate actions to prevent disasters, such as system instability or damage.

You can use the DRAC 5 to monitor hardware sensor for batteries, fan probes, chassis intrusion, power supplies, power consumed, temperature, and voltages.


Battery Probes

The Battery probes provide information about the system board CMOS and storage RAM on motherboard (ROMB) batteries.

NOTE: The Storage ROMB battery settings are available only if the system has a ROMB.

Fan Probes

The fan probe sensor provides information on:

  • fan redundancy — the ability of the secondary fan to replace the primary fan if the primary fan fails to dissipate heat at a pre-set speed.

  • fan probe list — provides information on the fan speed for all fans in the system.


Chassis Intrusion Probes

The chassis intrusion probes provides status of the chassis, whether chassis is open or closed.


Power Supplies Probes

The power supplies probes provides information on:

  • status of the power supplies, whether within the normal threshold value or has crossed threshold value.

NOTE: You can set threshold values only from the Dell™ OpenManage™ Server Administrator. See the Dell OpenManage Server Administrator User's Guide for more information.
  • power supply redundancy, that is, the ability of the redundant power supply to replace the primary power supply if the primary power supply fails.

NOTE: If there is only one power supply in the system, the Power Supply Redundancy section will not display.

Hardware Performance Probes

The hardware performance sensor provides status of the performance of your central processing unit (CPU), whether degraded or normal. The status of the hardware performance sensors is degraded when the CPU is in throttled state.


Power Monitoring Probes

Power monitoring provides information about the real time consumption of power, in watts and amperes. This information is provided to the DRAC 5 through the baseboard management controller (BMC) firmware sensors.

NOTE: This feature is supported only on limited Dell PowerEdge™ x9xx and xx0x systems.

You can also view a graphical representation of the consumption of power for the last one hour, day, or week from the current time set in the DRAC.


Temperature Probes

The temperature sensor provides information about the system board ambient temperature. The temperature probes indicate whether the status of the probes is within the pre-set warning and critical threshold value.


Voltage Probes

The following are typical voltage probes. Your system may have these and/or others present.

  • CPU [n] VCORE

  • System Board 0.9V PG

  • System Board 1.5V ESB2 PG

  • System Board 1.5V PG

  • System Board 1.8V PG

  • System Board 3.3V PG

  • System Board 5V PG

  • System Board Backplane PG

  • System Board CPU VTT

  • System Board Linear PG

The voltage probes indicate whether the status of the probes is within the pre-set warning and critical threshold values.