The following tables provide specification information about the PowerVault
132T library.
Dimensions
Weight
Library with 1 drive
46 lbs (20.9 kg)
Library with 2 drives
54 lbs (24.5 kg)
Storage Slot Count
LTO
SDLT
Rear Tape Slots
9
8
Magazine Slots
7
6
Magazines per Library
2
2
Import/Export Slot (configured as a data slot)
1
1
Total Tape Slots
24
21
Library Storage Capacity
Tape Capacity
Library Capacity
LTO-1
100 GB
2.4 TB
SDLT-320
160 GB
3.36 TB
LTO-2
200 GB
4.8 TB
LTO-3
400 GB
9.6 TB
Library Data Transfer Rates
Drive Transfer Rate
Uncompressed
1 Drive
2 Drives
IBM LTO Ultrium 1
15 MB/s
54 GB/hr
108 GB/hr
Quantum SDLT-320
16 MB/s
57.6 GB/hr
115.2 GB/hr
IBM LTO Ultrium 2
35 MB/s
126 GB/hr
252 GB/hr
IBM LTO Ultrium 3
80 MB/s
288 GB/hr
576 GB/hr
Operating Time
Average Cartridge Move Time
13.6 seconds
Safety and EMC Standards
Safety
CSA Standard CAN/CSA-C22.2 no. 950-95
UL Standard 1950, Third Addition
EN60950
Emissions
FCC #47, Part 15, Subpart B, Class A;
ICES-003 (Canada);VCCI Class A (Japan);
BSMI CNS 13438 (Taiwan);
EN55022:1994; EN61000-3-2:2001;
EN61000-3-3:1998 (Europe);
AS/NZS 3548:1995 (Australia/NZ)
Immunity
EN 55024:1998 ITE – Immunity Characteristics, Limits & Methods of Measurement;
European Union CE Immunity Standards
Power
Input Power
100–240 VAC, 50–60 Hz, 4.0–1.7 A
Power Consumption
(includes barcode scanner,
RMU, SCSI Terminators)
RMS Power
(W)
Peak Power
(W)
LTO-1
LTO-2
LTO-3
SDLT
LTO-1
LTO-2
LTO-3
SDLT
One Drive
104
89
76
104
162
147
122
157
Two Drives
179
149
123
179
290
260
210
280
Two Drives with SNC
253
223
197
253
376
346
296
366
Thermal Environment
Operating
Non-operating
Shipping & Storage
Dry Bulb Temperature
10ºC to 38ºC
(50ºF to 100ºF)
@2000 M
10ºC to 33ºC
(50ºF to 91ºF)
@3000 M
10ºC to 45ºC
(50ºF to 113ºF)
-40ºC to 65ºC
(-40ºF to 149ºF)
Temperature Variation
3ºC (5.5ºF)
per Minute Max
3ºC (5.5ºF)
per Minute Max
3ºC (5.5ºF)
per Minute Max
Wet Bulb Temperature
29ºC (84ºF)
Max
32ºC (90ºF)
Max
37ºC (99ºF)
Max
Relative Humidity
10 to 90%
10 to 90%
10 to 95%
Mechanical Environment
Non-Operating Shock and Vibration
Swept Sine
Range
Peak G
Desktop & Rackmount
3-500-3
1.0
Random Vibration
Frequency
G2/Hz
Desktop &
Rackmount
2
4
8
40
55
70
200
500
1.0x10 -3
3.0x10 -2
3.0x10 -2
3.0x10 -3
1.0x10 -2
1.0x10 -2
1.0x10 -3
1.0x10 -3
Shock
Pulse Amplitude (G)
Pulse Width
Desktop
V
H
Rackmount
V
H
150
100
100
100
2
2
3
3
Operating Shock and Vibration
Swept Sine
Range
Peak G
Desktop & Rackmount
3-500-3
0.3
Random Vibration
Frequency
G2/Hz
Desktop
5
17
45
48
62
65
150
200
500
2.0x10 -7
2.2x10 -5
2.2x10 -5
2.2x10 -5
2.2x10 -5
2.2x10 -5
2.6x10 -5
2.2x10 -5
2.2x10 -2
Rackmount
5
17
45
48
62
65
150
200
500
2.0x10 -5
1.1x10 -3
1.1x10 -3
8.0x10 -3
8.0x10 -3
1.0x10 -3
1.0x10 -3
5.0x10 -4
5.0x10 -4
Shock
Pulse Amplitude (G)
Pulse Width
Desktop
V
H
Rackmount
V
H
75
50
50
50
2
2
3
3
Shipping Shock and Vibration
Sinusoidal
Frequency
Peak (G)
All three axis
2 200 2
0.5 g
Random Vibration
Frequency
PSD Level (G2/Hz)
All three axis
2
4
8
40
55
70
200
0.0010
0.0300
0.0300
0.0030
0.0100
0.0100
0.0010
Shock
All six faces
Acceleration: 25 G,
25 ms, Square wave
Velocity: 55.5 m/s change in half sine wave pulse,
2-3 ms duration
Drop
Height
All six faces, 1 edge, 1 corner
24"
Acoustic
Designation
Class 3C Table Top Unit
Upper Limit of Operating Sound Power*
62 dB (6.2 Bels)
Upper Limit of Idle Sound Power**
60 dB (6.0 Bels)
Maximum Operator Position Sound Pressure
61 dB
*Operating is defined as exercising both robotic and tape drive
components.
**Idle mode is defined as the unit being powered on with no robotic
or tape drive action.
Library Interface
SCSI
The library can communicate through external HD 68 pin SCSI connectors
on the Drive Module.
LVD
Fibre Channel
The library can communicate through FC drives. A fibre channel
interface is also provided in the optional Storage Networking Controller.
It will support 50 Micron Multi-Mode Short-wave and 65 Micron Multi
Mode Fibre.
Reliability
MTBF (Mean Time Between Failures)
100,000 hours
MTTR (Mean Time To Repair)
Less than 30 minutes
MSBF (Mean Swap Between Failures)
(A swap is defined as a pick and a place followed by a pick and a place)